Description

Driver for sending annotation messages (Fix Marks, SOL / EOL Info, Fix Event Info, etc.) to echosounders.

This is a driver with user-interface, so settings can be changed online by clicking on the system button in the task bar.

The format of the annotation output string can be selected online, under Settings – Annotation.

By default, no header is added before the output message. There are also possibilities to send direct annotation messages.

The Annotation Driver will display an overview of your selections:

  • Driver: port and format
  • Annotation: format and when fix out
  • Annotation: what is being output upon fix

Driver Information

Driver Text Annotation  Interface Type Serial Driver Class Type Counted/Terminated
UTC Driver (question)  No Input / Output Output Executable  DrvAnnotate.exe TEXTOUT
Related Systems
Related Pages


Database Setup

In Database Setup, add a "Closure Output system":

Name For example: "Closure Output System".
Type  Closure Output System.
Driver Text Annotation.
Port Number As set up on Qinsy PC to output a proper signal.

Leave the Closure Parameters page at its defaults. Settings will not be used for this driver unless a QPS fix box is in use.


Online

When working Online in the Controller, closures will only be generated depending on the Fix setup as set in the Session Setup > Fixing section.

For more information on how to set up fixes, please visit this link:


Driver use


When going Online the user interface dialog box for this driver is typically minimized in the task bar at the bottom of the screen.

On maximizing, click the 'Plus' button to select the Annotation sentence(s) to be output.

Annotation Settings

Select and/or tick what you would like to output via this driver

  • Annotation Format: Select the format to be outputted by the driver: Text Out
  • Annotation Trigger: Select how you want to annotate the trigger
  • Annotation Output: Select what your output information will be


Annotation Format


Format Type Select Text Out, which is a regular text output.
Annotation Triggering

Never (disabled)

This option will never output an annotation upon any trigger (unless you manually trigger).

When fixnumber updates

Output annotation when the fixnumber in Qinsy increments.
When recording is active Output annotation when the fixnumber in Qinsy increments but only during an actual recording.
Annotation Output
Fixmarks (straight lines) Signal out for indicating a new fix.
SOL/EOL Information Information out for indicating SOL (start of line) or EOL (end of line).
Fix Event Information Event information output as set in 'Settings'. (See below.)

Fix Information - Settings

Select 'Settings' next to 'Fix Event Information' to set up your output string.

The following dialog opens:


Select Node


Steered Node to determine position or line offsets

Tick this if you would like the steered node to be used to determine the position or the line offsets.
The steered node can still be set up in Computation Setup, where you can select the node for which the fix is to be calculated.

Adjustment Which computation should be used for Fix event out.
Node Which node should be used for Fix event out.
Annotation String

Fix number preceded by Character

Current fixnumber + Character of choosing.

UTC time of fix event (HH:MM:SS)

Tick to add UTC time instead of local time.
Position (Easting, Northing) Position of the selected node.
KP (Route) or MP (Line) KP along the route or MP along the line.
Distance Offline Distance in meters off the selected line.
E/S Depth Echosounder depth.
Transducer When E/S Depth was actived, select the Transducer here.