My Issues

Drivers Manual

Standard RMI (1 Observation) - 23

Description

Driver for decoding RMI values from systems that output in standard RMI 

Driver Information

Driver Standard RMI (1 Observation)  Interface Type Serial Driver Class Type Terminated
UTC Driver (question) No Input / Output Input Executable  DrvStandardRMI.exe
Related Systems
Related Pages  



Decoding Notes

In case of no valid data the output string is <LF>A+9999<CR>.

When this happens the quality indicator is set to '-1', otherwise it is 1. 

Interfacing Notes

A simple one-way wired RS-232 cable is enough.

However, a bi-directional cable is more practical.